ASSEMBLY GUIDE
ClicPCB Core Edition Kit
System Overview
The ClicPCB kit is a modular platform designed for:
- Mechanical integration of PCBs
- Structured organization of electronic assemblies
- Scalable prototyping
- Controlled electrostatic management
The system is intended for:
- Advanced makers
- System integrators
- Hardware developers
- Advanced technical environments
Kit Contents
The kit includes:
- Structural tubular segments
- ESD dissipative angle connectors
- PCB supports
- Copper conductor for electrostatic management
- Technical documentation
All connectors in the Core Edition kit are made from ESD dissipative material.
Modular Principle
The system enables:
- Linear assembly
- Square structures
- Cubic structures
- Multi-level configurations
- Certified ClicPCB extensions
All components are mechanically compatible.
Electrostatic Management (ESD)
Principle
The structure can be referenced to the GND of an electronic system in order to:
- Limit charge accumulation
- Reduce local potential gradients
- Equalize structural potential
The system is not a Faraday cage. It is a referenced dissipative structure.
Supplied Copper Ground Wire
The kit includes a copper conductor (5 m).
Recommended typical usage:
30 cm to 1 m, depending on configuration.
The conductor is intended to:
- Create one or more GND reference points
- Connect the structure to the GND of a PCB
It is recommended to properly strip the wire ends before connection.
General Grounding Rules (GND)
Fundamental Principle
A GND point defines a reference.
Multiple connections without proper design may create conductive loops.
Linear Structure (n segments)
Example: aligned segments
1 GND point is sufficient
2D Closed Structure (square / rectangle)
Do not connect all four segments simultaneously.
| Usage | Recommanded GND Points |
| Standard | 1 |
| Sensitive | 2 opposite segments |
3D Structure (cube – 12 segments)
Avoid any fully closed conductive loop.
| Usage | Recommanded GND Points |
| Standard | 1 base |
| Optimized | 2 opposite base |
| Advanced | Max 3 ( 2 base + 1 opposite vertical ) |
Multi-Level Structure
Recommended rules:
- 1 to 2 GND points per horizontal level
- Symmetrical distribution
- No conductive loop
GND Summary Table
| Structure Type | Recommanded GND Points |
| Line | 1 |
| Square | 1 to 2 |
| Cube | 1 to 3 |
| Multi-level | 2 to 4 maximum |
RF Recommendations
For RF modules (433 MHz, WiFi, GSM, etc.):
- Keep antennas at least 15 mm away from structural segments
- Do not create a fully closed conductive loop
- Prefer partially grounded structures
The ClicPCB structure is not an RF shielding system.
Certified ClicPCB Extensions
Certified extensions:
-
Ensure mechanical compatibility
- Respect GND topology
- Follow RF recommendations
- Maintain system consistency
Each certified extension includes:
- Reference
- Version
- Validation date
Scalability
ClicPCB is a scalable platform.
All certified extensions are:
- Backward compatible
- Documented
- Validated according to ClicPCB internal criteria
Conditions of Use
ClicPCB is intended for:
- Prototyping
- Development integration
- Functional testing
This system:
- Is not industrially certified
- Is not ATEX certified
- Is not a regulatory grounding system
Important Recommendation
Electrostatic management:
- Reduces risks
- Does not replace standard ESD best practices
- Does not replace a certified environment
A Complete Solution
Featuring 21 categories of components, each supplied in multiple units, the ClicPCB kit enables an extensive range of configurations and assemblies.
All parts are fully reusable and designed for long-term use, with convenient storage in a dedicated case for optimal organization.